HPLC-Zubehφr
|
INFO: |
PTFE Rohre (PolyTetraFluorEthylen) |
||
|
All the PTFE tubings and capillaries are extruded from virgin PTFE manufactured exclusively by Dupont, the original manufacturer of PTFE material. We do not add any additives to the original PTFE material, except for color particles in the solid colored tubing. PTFE tubing and capillaries are widely used in all low-pressure laboratory applications. Please be aware that all PTFE tubing does contain micro-pores in the tubing wall. These micro-pores allow a quick air exchange. This is of special consideration for degassed and oxygen-sensitive solvents.
Tolerances for PTFE tubing and capillaries is as follows: up to 2.0 mm: +/- 0.10 mm 2.0 mm and above: +/- 0.20 mm |
|
||
|
naturfarben |
|||
|
Kat.-Nr. |
Beschreibung |
Druck (bar/psi) |
|
|
42.159.018.00 42.159.025.00 42.159.050.00 42.159.075.00 42.159.100.00 42.200.170.00 42.318.159.00 42.318.240.00 42.635.475.00 42.400.300.00 |
Tubing, PTFE, 1/16 OD x 0.18 mm ID Tubing, PTFE, 1/16 OD x 0.25 mm ID Tubing, PTFE, 1/16 OD x 0.50 mm ID Tubing, PTFE, 1/16 OD x 0.75 mm ID Tubing, PTFE, 1/16 OD x 1.00 mm ID Tubing, PTFE, 2.00 mm OD x 1.70 mm ID Tubing, PTFE, 1/8 OD x 1/16 ID Tubing, PTFE, 1/8 OD x 2.40 mm ID Tubing, PTFE, 1/4 OD x 4.75 mm ID Tubing, PTFE, 4.00 mm OD x 3.00 mm ID |
60 / 850 55 / 800 50 / 725 35 / 510 25 / 365 10 / 150 35 / 510 20 / 290 20 / 290 20 / 290 |
|
|
|
|||
|
einfarbig |
|||
|
Kat.-Nr. |
Beschreibung |
Druck (bar/psi) |
|
|
42.159.025.51 42.159.050.52 42.159.075.53 42.159.025.57 42.159.050.57 |
Tubing, PTFE, 1/16 OD x 0.25 mm ID, blue Tubing, PTFE, 1/16 OD x 0.50 mm ID, orange Tubing, PTFE, 1/16 OD x 0.75 mm ID, green Tubing, PTFE, 1/16 OD x 0.25 mm ID, black Tubing, PTFE, 1/16 OD x 0.50 mm ID, black |
55 / 800 50 / 725 35 / 510 55 /725 50 / 725 |
|
|
|
|||
|
|
Reaktionsrohr PEEK (knitted reaction coils) |
||
|
lenght |
ID = 0,25 mm |
ID = 0,50 mm |
ID = 0,75 mm |
|
1 m 2 m 4 m 10 m 20 m |
42.159.025-1 42.159.025-2 42.159.025-4 42.159.025-10 42.159.025-20 |
42.159.050-1 42.159.050-2 42.159.050-4 42.159.050-10 42.159.050-20 |
42.159.075-1 42.159.075-2 42.159.075-4 42.159.075-10 42.159.075-20 |
|
|
|||
|
Note: The data collected in column Pressure show the recommended permanent maximum working pressure at room temperature for non-destructive solvents. Change of solvents and temperature may result in lowered mechanical stability. Keep in mind that tight bends of the tubing, use of wrong tools for cutting and bad connections may result in mechanical damage to the tube and by this reduce the pressure stability. |
|||