CLEAN SCREEN® - RSV
Reduced Solvent Volume Extraction Columns
|
|
|
|
|
|
|
|
Reduced Solvent Volume extraction columns are micro bed packed columns which offer the advantages of disc technology yet maintain the proven track record of our conventional SPE columns. Reduced Solvent Volume columns use 75% less solvent than traditional packed columns. Less solvent means faster extractions, higher throughput and less waste disposal, which translates into significant savings in both time and money. Results demonstrate that therapeutic and abused drugs in urine and blood matrices can be extracted with cleanliness, high recoveries and consistent reproducibility by using the Reduced Solvent Volume extraction column.
RSV columns are available in 1 mL, 3 mL and 10 mL configurations. These columns can be used with vacuum manifolds or positive pressure, as well as conventional automated extraction equipment. |
|||||
|
Advantages of CLEAN SCREEN® RSV:
|
|||||
|
Absolute Recovery
THC-COOH Standards (ng/ml) in spiked urine |
Capacity 91% (n=4) for 1000 ng/ml 90% (n=2) for 3000 ng/ml 91% (n=4) for 4000 ng/ml
No Analyte breakthrough at 1000 ng/ml and less than 0.2% analyte breakthrough at 3000 and 4000 ng/ml levels. |
|
Concentration (ng/ml)
Analyte |
Recovery
Linear Ranges Exhibiting Greater than 85% Recoveries in Urine
=== Highest Concentrations Tested === Lowest Concentrations Tested |
|
Solvent Reduction |
|||
|
Analyte |
Solvent Usage Reduced Solvent Volume SPE columns |
Solvent Usage Traditional Packed columns |
% Solvent Reduction |
|
Barbiturates Benzoylecgonine THC-COOH Phencyclidine |
4.25 mL 4.65 mL 4.85 mL 5.15 mL |
18 mL 19 mL 16.4 mL 19 mL |
76% 76% 73% 70% |
|
Copolymeric Extraction for All Drug Classes |
|||
|
Part Number With Clean-Thru® Tips CSDAUA51 CSDAUA83 ZSDAUA08Z |
Part Number Without Clean-Thru® Tips CCDAUA51 CCDAUA83 ZCDAUA08Z |
Sorbent Amount/ Tube Volume 50mg/1mL 80mg/3mL 80mg/10mL |
Unit per Pack 100 50 50 |
|
CLEAN SCREEN® DAU Column is copolymerized on a rigid, purified silica gel support. The two functional groups include a reverse phase, and an ion exchanger, benzenesulfonic acid. This column is commonly used for analyzing a wide range of drugs of abuse, including acidic, basic and neutral drugs. |
|||
|
Specifically for THC & THCA Extraction |
|||
|
Part Number With Clean-Thru® Tips CSTHCA51 CSTHCA83 ZSTHCA08Z |
Part Number Without Clean-Thru® Tips CCTHCA51 CCTHCA83 ZCTHCA08Z |
Sorbent Amount/ Tube Volume 50mg/1mL 80mg/3mL 80mg/10mL |
Unit per Pack 100 50 50 |
|
CLEAN SCREEN® THC Column is copolymerized on a rigid, purified silica gel support. The two functional groups include a reverse phase, and an ion exchanger, quaternary amine. This column is commonly used for analyzing THC and its metabolites. |
|||
CLEAN-UP® - RSV
Reduced Solvent Volume Extraction Columns
|
C18, Octadecyl Tri-Functional |
||||
|
Part Number Endcapped CEC18A051 CEC18A083 CEC18A08Z |
Part Number Unendcapped CUC18A051 CUC18A083 CUC18A08Z |
Sorbent Amount/ Tube Volume 50mg/1mL 80mg/3mL 80mg/10mL |
Unit per Pack 100 50 50 |
% Organic Loading: 21.70 Application: Removes hydrophobic impurities, de-salting and purification of hydrophobic compounds. |